Difference between revisions of "Soft Stop"

From youBot wiki
Jump to: navigation, search
(Base)
Line 23: Line 23:
 
In order to use the stop functionality you have to remove this jumper first.
 
In order to use the stop functionality you have to remove this jumper first.
 
2.2 Connect a switch to the SOFT_STOP connector
 
2.2 Connect a switch to the SOFT_STOP connector
[[File:softstop4.png|thumb|center|600px|Arm jumper]]
+
 
 
After removing the „stop jumper“ you can now connect a switch to the SOFT_STOP connector of
 
After removing the „stop jumper“ you can now connect a switch to the SOFT_STOP connector of
 
the masterboard (see picture above for the connector).
 
the masterboard (see picture above for the connector).
Line 29: Line 29:
 
open, the communication and the joints will stop. For the pin configuration of the JST B3B-PH
 
open, the communication and the joints will stop. For the pin configuration of the JST B3B-PH
 
connector see the table below.
 
connector see the table below.
 +
[[File:softstop4.png|thumb|center|600px|Pin configuration]]

Revision as of 14:24, 19 December 2014

WHAT IS SOFT STOP


Arm

The arm masterboard provides a soft stop mechanism which will disable any communication among the five arm axes controllers and any external devices. A communication loss will put the modules into a safe mode. 1.1 Connect a switch to the stop interface of the connector board After removing the „stop jumper“ you can now connect a switch to the stop interface of the connector board.

Arm jumper

If the SOFT_STOP pin is connected to the ground, the etherCAT communication is activated. If it is open, the communication and the joints will stop. For the pin configuration of the RJ11 (6P4C) connector see the table below.

Arm jumper

Base

The base masterboard provides a soft stop mechanism which will disable any communication between the four axes/wheel controllers and any external device. A communication loss will put the modules into a safe mode. 2.1 Remove Jumper first

Base jumper

The masterboard contains a single jumper which bypasses the soft stop functionality of the board . In order to use the stop functionality you have to remove this jumper first. 2.2 Connect a switch to the SOFT_STOP connector

After removing the „stop jumper“ you can now connect a switch to the SOFT_STOP connector of the masterboard (see picture above for the connector). If the SOFT_STOP pin is connected to the ground, the etherCAT communication is activated. If it is open, the communication and the joints will stop. For the pin configuration of the JST B3B-PH connector see the table below.

Pin configuration